
29
DXA scanners live
At hospitals and clinics across Canada
6,134+
BMD reports delivered
Produced across those sites to date
36+
Languages supported
Patients answer in their own language, on site
In use at hospitals and clinics across Canada














25 min → 15 min per patient
18 → 28 cases per day
5 min → less than 30s
Report
Patient
SAMPLE, PATIENT
MRN
SMP-100412
Accession
1915199576004821
Date of birth
1951-02-14 (age 75)
Sex
Female
Study date
2026-06-12
Bone Mineral Density
DENSITY (g/cm²) | T-SCORE | Z-SCORE | DENSITY PRIOR (g/cm²) | CHANGE (g/cm²) | CHANGE (%) | |
|---|---|---|---|---|---|---|
| Spine L2-L4. | 0.835 | -2.5 | -0.2 | 0.874 | -0.039 | -4.5 |
| Right Femoral Neck. | 0.631 | -2.6 | -1.1 | |||
| Right Total Hip. | 0.590 | -3.4 | -1.9 | 0.615 | -0.025 | -4.1 |
DIAGNOSTIC CATEGORY: Osteoporosis.
10-YEAR MAJOR OSTEOPOROTIC FRACTURE RISK (FRAX): 20.0%
RISK FACTORS: Glucocorticoids (Chronic). Secondary Osteoporosis. Cortisone (50 mg) 2025-01 - (ongoing). Aromatase inhibitors.
BONE-ACTIVE DRUG THERAPY: No.
LIMITATIONS: Vertebra(e) has/have been excluded from analysis as the T-score(s) is/are at least one standard deviation greater than the T-score of the vertebra with the next highest value. The left hip was not assessed due to orthopedic intervention. Fracture risk is likely underestimated because an osteoporotic T-score at the lumbar spine, femoral neck, or total hip is not accounted for in FRAX.
RECOMMENDATIONS: Pharmacotherapy is recommended as per the 2023 Osteoporosis Canada guideline.
FOLLOW-UP: 1 year, given significant interval bone loss.
LSC (least significant change) at Westview Imaging Centre: Lumbar Spine - 0.031 gm/cm² Total Hip - 0.019 gm/cm²
A real report from DXA Encode, shown in full. Nothing here was typed by hand.
Measurements already sit in the DICOM SR. Reading them directly means nobody re-types a value.
Priors come forward and change is calculated, so most of the appointment becomes a review.
The draft arrives written with the current guideline applied. The radiologist signs rather than composes.
Guidelines change; we track them. Updates to the logic, the recommended treatment and the follow-up intervals arrive ready for your approval, so every report reflects current best practice without anyone having to re-learn a template.
Obstetric ultrasound. Structured trimester worksheets with biometry, fluid and Doppler mapped from the DICOM SR, growth plotted against priors, and completeness enforced against reporting standards.
Ask about early access“Seamless training and implementation. Quick, accurate.”
Chris
Technologist, MRT, CDT